The OCPP 2.0.1 BootNotification
- ocpp
- boot
- websocket
When a charging station opens its OCPP-J WebSocket to the CSMS, the first application message it sends is almost always a BootNotification. It is the station introducing itself, and it is the single richest message for figuring out what just connected to your bench.
The request
A BootNotification request carries a reason and a chargingStation object:
[2, "9f1c2d3e-4b5a-4c6d-8e7f-0a1b2c3d4e5f", "BootNotification", {
"reason": "PowerUp",
"chargingStation": {
"model": "CBOX 01",
"vendorName": "MyBox",
"serialNumber": "SN-000123",
"firmwareVersion": "1.4.2",
"modem": { "iccid": "…", "imsi": "…" }
}
}]
What the reason tells you
The reason is a BootReasonEnumType, and it is the station telling you why
it just booted. The values you will actually care about on the bench:
- PowerUp: a cold start (e.g. mains power returned).
- RemoteReset: the station rebooted after a
Resetcommand from the CSMS. - FirmwareUpdate: it just came back from flashing new firmware.
- ScheduledReset: a
Resetwith typeOnIdlethat the station deferred while a transaction was still running, then carried out once the connector went idle. - ApplicationReset: the OCPP application itself crashed and restarted.
- Watchdog: the application hung, the watchdog timer elapsed, and the OS killed and restarted it.
Those last two are the interesting ones. A station that reports Watchdog or
ApplicationReset every few hours is not having a good time, and the boot
reason is often the only breadcrumb you get. If you are chasing a reconnect
loop, this field is the first thing to read.
The response
The CSMS answers with a CallResult carrying status, currentTime and
interval:
[3, "9f1c2d3e-4b5a-4c6d-8e7f-0a1b2c3d4e5f", {
"status": "Accepted",
"currentTime": "2026-07-15T09:00:00Z",
"interval": 300
}]
currentTime: the station's first clock sync
It is easy to skim past currentTime, but it is doing real work. It is the
CSMS's current wall-clock time, and for many stations it is the first
accurate time they have after booting.
A charge point without a battery-backed RTC has no idea what time it is when it
comes up from a power cycle (its clock starts from some firmware default).
Until it learns the real time, every timestamp it produces (transaction
start/stop, meter values, log entries) is wrong. The currentTime in the
BootNotificationResponse is where it fixes that: when the station is configured
to take its time from the CSMS, it synchronizes its internal clock to this
value (OCPP 2.0.1 B01.FR.06) and then keeps it in sync through the
currentTime in every subsequent HeartbeatResponse.
So a BootNotification is not just a "hello!". For an RTC-less station it is also the moment its clock becomes trustworthy. If transaction timestamps on the bench look decades off, check that the station is actually applying this value.
What interval means (it depends on status)
The meaning of interval changes with status:
- Accepted: the station is registered.
intervalis the heartbeat period in seconds. - Pending: the CSMS wants to configure the station before accepting it.
intervalis how long to wait before sending the next BootNotification. - Rejected: the station must wait
intervalseconds and try again.
Why it matters on the bench
Because the BootNotification is where firmware bugs surface first. A model name that does not match the label, a serial number that changes across reboots, a firmware string that never updates after a flash, a clock that never gets set. All of it shows up here, before a single transaction has run. Watch this message to identify incorrect charge point behavior early.
Watching it in practice
By hand you only ever see the boot in front of you. What matters is the pattern across many boots, and whether the station really obeys the response you sent it.
The second one is worth a closer look. interval means three different things
depending on status, so it is exactly the kind of branch that should not ship
untested. And currentTime has to be adopted by the station (B01.FR.06). You
check both with a response you define yourself and a look at what the station
does next.
In EVSExplorer you define that response yourself, through
canned answers per action (with autoResponseMode
set to defined or all):
# Reject the next boot and tell the station to wait ten minutes
curl -s -X PUT $BASE/api/charge-points/CS001/auto-responses/BootNotification \
-H 'Content-Type: application/json' \
-d '{"status": "Rejected", "currentTime": "%UTC_TIMESTAMP%", "interval": 600}'
# Watch what it does next, heartbeat noise filtered out
curl -s "$BASE/api/charge-points/CS001/message-logs?exclude_actions=Heartbeat&limit=20"
A station that reconnects immediately instead of waiting out those 600 seconds
can overload a CSMS that is trying to shed load. %UTC_TIMESTAMP% is filled in
at send time. Put a fixed date there instead, then check whether the station
adopted the new time.
Vendor, model, serial number and firmware version are lifted out of the BootNotification onto the station's own record, so the dashboard card shows what is on the bench and which OCPP version it is using.
The firmware version is worth a second look, because every logged frame records the version the station was running when it sent that frame. The message history will therefore answer questions no single boot can: did the firmware string ever change after we flashed it, is this malformed value genuinely gone in the new build or just rarer, and what does the firmware history of this station actually look like?